Top of page
Skip to main content

Combining fsQCA with SEM, NCA, ANN and longitudinal designs

Choose how to combine fsQCA with CB-SEM, PLS-SEM, NCA, ANN, Delphi and longitudinal data. Distinguish modeled relationships, necessity, sufficient configurations and prediction through ten critically assessed applications.

An integrated design assigns distinct tasks: SEM evaluates specified relationships, NCA assesses necessity constraints, fsQCA examines set-theoretic configurations, and ANN assesses prediction. Delphi and temporal designs add design information. Their indices are not interchangeable, and multiple analyses of one sample are not independent validations.

Start reading

1. Different analytical claims

Dul (2016, pp. 10–15) distinguishes sufficiency, where X is enough for Y, from necessity, where Y cannot be achieved without X. A necessary condition acts as a bottleneck: other favorable factors cannot compensate for its absence at the relevant outcome level. A conventional additive coefficient does not directly test that claim.

Richter et al. (2020) describe the practical distinction between conditions that contribute to an outcome and conditions that must meet a minimum. fsQCA adds a configurational question concerning combinations associated with the outcome.

Table 1. Three analytical questions. The management examples are hypothetical illustrations.
MethodFocusQuestionExample claim
PLS-SEMRelationships conditional on the specified modelHow is X related to Y in that model?Managerial support is positively related to engagement.
NCANecessity at different levelsWhat minimum X constrains a target level of Y?High engagement requires at least a specified level of support.
fsQCANecessary or sufficient set relationsWhich combinations are associated with Y?Support with autonomy, or rewards with advancement, forms alternative recipes.

The word “sufficiency” sometimes used for variance-based explanatory reasoning should not be confused with establishing X ⊆ Y. A coefficient and a set inclusion are distinct analytical objects.

2. Necessity in fsQCA

X is necessary for Y when Y is a subset of X. Necessity consistency is Σmin(X, Y) / ΣY (Ragin, 2008, p. 52). With X on the horizontal axis and Y on the vertical axis, perfect necessity requires Y ≤ X: points lie on or below the diagonal.

A consistency threshold of 0.90 is a common convention, to be interpreted alongside calibration, coverage, relevance and deviant cases (Greckhamer et al., 2018, p. 489). Necessity coverage, Σmin(X, Y) / ΣX, helps assess how empirically relevant the condition is. An almost universally present condition may be trivially necessary because it offers little constraint (Ragin, 2008, pp. 59–60).

Do not lower a threshold just to obtain necessity

Vis and Dul (2018, pp. 892–893) discuss the risk of false necessity claims. If no condition meets a justified necessity criterion, report that result. NCA can ask a different degree-oriented question; it does not rescue a preferred conclusion by changing the meaning of the original test.

3. NCA: ceilings and empty space

A potential necessary relationship appears as an empty upper-left region in a scatterplot: high Y is not observed with low X. NCA estimates a ceiling separating that region from observations (Dul, 2016, pp. 16–28). CE-FDH uses a stepwise envelope; CR-FDH uses a linear approximation and may leave exceptions above the fitted ceiling. The ceiling choice needs justification from the measurement and data.

Effect size d

The ceiling-zone area relative to the selected scope describes the size of the constraint. Dul's (2016) small, medium and large categories are descriptive conventions, not an independent license to claim causality. Consider scope, ceiling choice, error and substantive relevance.

Accuracy

The proportion of cases on or below the ceiling. Observations above it are exceptions to the proposed constraint. Report their number and location rather than treating 95% as an acceptance rule for every setting.

Significance assessment

The approximate permutation test evaluates evidence against an effect arising by chance (Dul et al., 2020). Statistical evidence and substantive importance are separate considerations.

Bottleneck table

Report the minimum levels associated with target outcome levels. Where several conditions are necessary, each bottleneck needs to be met; meeting them does not by itself guarantee the outcome.

Dul (2016, pp. 35–36) emphasizes measurement, meaningful scope and whether low condition values actually occur. The ceiling and apparent empty space can be sensitive to measurement error, particularly near the boundary. NCA alone does not identify a causal relationship.

4. Necessity in kind and in degree

Vis and Dul (2018, pp. 873–874, 891–893) contrast a set-necessity criterion with the degree-oriented constraints examined by NCA. Fuzzy-set necessity uses a particular diagonal inclusion relation; NCA allows different ceilings. A difference between the results can therefore reflect different questions rather than a computational contradiction.

In their reanalysis of 76 cases, the highest single-condition fsQCA necessity consistency was 0.891, below a 0.90 criterion. NCA found an effect of approximately d = 0.23 for that condition and constraints at outcome levels of 0.50 and above; the authors also compare necessary AND combinations (Vis & Dul, 2018, pp. 883–891). These are findings from that published example, not a promise that NCA will find necessity in every new dataset.

Use degree-oriented necessity reasoning when the substantive question concerns a minimum level for a target outcome. Both the interpretation and the measurement must support that question.

Inputs need meaningful scales

fsQCA requires calibrated membership in defined sets. NCA needs ordered or quantitative information supporting a minimum-level interpretation; arbitrary codes for unordered nominal categories do not become meaningful amounts. Latent scores may be used before and after calibration, respectively, if the scoring and transformations are justified.

5. An integrated workflow

Rasoolimanesh et al. (2021) provide guidance on combining PLS-SEM and fsQCA; Richter et al. (2020) address PLS-SEM and NCA. Sukhov et al. (2023) illustrate a three-method approach. The following workflow synthesizes those complementary aims without treating the analyses as interchangeable.

Theory for each claim

Specify relationship hypotheses, necessity hypotheses and configurational propositions separately.

Measurement assessment

Assess reliability and construct validity appropriate to the measurement model before extracting scores.

Structural relationships

Examine path estimates, uncertainty and predictive performance appropriate to the PLS-SEM question.

Necessity and bottlenecks

Evaluate NCA ceilings, d, permutation evidence, exceptions and target-level bottlenecks.

Calibration and configurations

Define sets, calibrate, inspect necessity, build truth tables and assess solutions and robustness for both outcome directions.

Joint interpretation

Compare the meanings of the findings and locate differences in the theoretical argument, measurement or analytical scope.

Do not compare coverage with R² to choose a winner

Pappas and Woodside (2021) discuss PLS-SEM and fsQCA findings on the same dataset, including R² of 0.57 and solution coverage of 0.84. These quantify different objects, not competing scores on one scale. Their difference is not evidence that one method explains more variance than the other.

6. Comparing the three methods

Table 2. A comparison drawing on Dul (2016), Vis and Dul (2018), Richter et al. (2020) and Pappas and Woodside (2021).
CriterionPLS-SEMNCAfsQCA
FocusSpecified conditional relationshipsPotential necessary constraintsSet relations and configurations
CompensationPossible in an additive specificationOther factors cannot compensate for a relevant bottleneck.Conditions are conjunctive within a recipe; alternative recipes can exist.
InputsIndicators and the measurement specificationMeaningful ordered or quantitative measuresCalibrated set memberships
Key resultsPaths, uncertainty, R² and predictive assessmentd, accuracy, permutation evidence and bottlenecksConsistency, PRI and coverage
InterpretationModeled relationshipsMinimum levels for target outcomesSufficient combinations and their core/peripheral elements
Practical questionWhich relationships merit attention?Which constraints must not be overlooked?Which combinations can be associated with the outcome?

7. Reporting, errors and a checklist

A rationale template

The theoretical framework contains three kinds of proposition. Relationship hypotheses [H1–Hn] are assessed with PLS-SEM. The necessity proposition [statement] is assessed with NCA, reporting ceiling [type], effect d [value], [number] permutations and bottleneck results (Dul, 2016; Dul et al., 2020). Configurational propositions [P1–Pm] are assessed with fsQCA after justified calibration (Rasoolimanesh et al., 2021). The discussion compares the findings and limitations. A necessity conclusion cannot be filled in from a d cutoff alone.
Table 3. Common integration errors.
Weak practiceProblemBetter practice
Use the same positive-effect hypothesis for all three methods.The propositions differ.Specify each analytical claim separately.
Infer necessity from a large coefficient.A conditional association is not a bottleneck.Evaluate the appropriate necessity relation.
Report d without significance assessment.Empty space can arise by chance.Report permutation evidence and substantive interpretation.
Lower necessity consistency to force a result.The intended criterion changes.Justify the criterion and report non-support where applicable.
Rank methods by R² versus coverage.The quantities are not comparable on one scale.Interpret complementary findings.

Before reporting the integrated design

  • Each method has a theory-based hypothesis or proposition.
  • Measurement is assessed before scores are extracted.
  • NCA includes the ceiling rationale, d, accuracy, permutation evidence and bottlenecks.
  • Potential trivial necessity is considered.
  • fsQCA includes justified calibration, necessary and sufficient relations and outcome negation.
  • The discussion compares results rather than merely listing three sets of tables.

8. When results do not agree

Do not force agreement. A path estimate, an NCA ceiling and a fuzzy-set inclusion are different objects. The integration guidance of Richter et al. (2020), Rasoolimanesh et al. (2021) and the example of Sukhov et al. (2023) support comparison rather than interchangeability. The table below contains hypothetical interpretations created for teaching.

Table 4. Hypothetical combinations of findings; these are not empirical results.
PatternDefensible interpretationUnsupported conclusion
A significant PLS-SEM path without strong necessity evidenceThe condition may contribute without being a mandatory bottleneck.It “must be present” because the path p-value is small.
An NCA bottleneck with a small average pathA low level may constrain the outcome even if increases beyond it show little average relationship.More X is always better, or meeting its minimum guarantees Y.
A condition present in one recipe and absent in anotherIts role depends on accompanying conditions.The analysis is automatically erroneous or has demonstrated moderation.

Document the scoring method, orientation and transformations of latent scores. A sample-standardized value does not automatically mean substantively high or low membership. Three analyses of the same observations also do not constitute three independent validations: the design and measurement limitations remain shared.

9. Choose the combination from the research question

A study does not need SEM, NCA and ANN simply because the software is available. Each addition should answer a distinct question using appropriate inputs and evaluation criteria. The following decision framework is an editorial synthesis of recent applications, not a mandatory protocol jointly proposed by their authors.

Table 5. Selecting an additional analysis by its purpose; editorial synthesis.
Additional questionPossible combinationOutput to inspect
Modeled relationships and alternative combinations associated with an outcomeCB-SEM or PLS-SEM + fsQCACoefficients, confidence intervals and measurement quality; configurations, consistency and coverage.
Minimum condition levels alongside sufficient combinationsNCA + fsQCA; add SEM only for a separate coefficient questionCeiling, d, permutation assessment and bottlenecks, distinguished from set-theoretic necessity.
Nonlinear prediction and outcome configurationsANN + fsQCA, or SEM + ANN + fsQCAError on data not used for model selection, an appropriate benchmark and stability of predictive importance.
Substantive grounds for calibration anchorsDelphi and measurement design before fsQCAExpert selection, consensus procedure, anchor meaning and mapping into original measurement units.
Stability across periods or groupsLongitudinal/panel design + fsQCA, with justified group comparisonsCase unit, timing, comparable set definitions and fit across periods and groups.

SEM applications include Zu et al. (2026), Choubey et al. (2026), Santoso et al. (2026), and Bai and Liu (2026). Elafdel (2026) and Xia et al. (2026) extend the design to ANN; Ogunmola et al. (2026) combine Delphi with longitudinal data. These are examples to learn from, rather than substitutes for justifying a design on one's own data.

10. Combining CB-SEM or PLS-SEM with fsQCA

PLS-SEM is not a prerequisite for fsQCA. Zu et al. (2026, Section 4.2) use AMOS for SEM before examining customer-experience configurations. Choubey et al. (2026, Section 4.1) use CFA and CB-SEM before fsQCA in an e-learning study. Measurement specification, objectives and estimation assumptions still govern the choice between CB-SEM and PLS-SEM. Planning a configurational stage does not by itself justify switching to PLS.

Before calibration, map constructs to indicators, scoring rules, orientation and substantive set definitions. Factor scores, latent-variable scores and composites all require justification; CFA or reliability assessment does not automatically turn them into membership values. Santoso et al. (2026, Section 3) illustrate a further distinction: SEM operates on higher-order constructs, whereas fsQCA examines lower-order components. A coefficient for an overall construct and a configuration containing one component do not test an identical proposition.

Bai and Liu (2026) illustrate a comparison between mediation modeling and outcome configurations. Including a mediator in a recipe does not estimate an indirect effect: co-membership in a sufficient combination and mediation concern different claims. A nonsignificant SEM path also does not automatically disqualify a theoretically relevant condition from fsQCA. Conversely, fsQCA should not be used to rescue unsupported SEM hypotheses.

Check what an application means by “NCA”

Table 5 in Santoso et al. (2026) is labeled NCA but reports set-theoretic consistency and coverage. That is insufficient evidence of Dul's ceiling-based NCA with d, permutation assessment and bottleneck tables. By contrast, Bai, Liu, and Ma (2026, Section 4.3) separately report CE/CR ceilings and fsQCA necessity. Classify a method from its calculations and outputs, rather than its acronym alone.

11. Add ANN for a nonlinear prediction question

Elafdel (2026, Section 4.4) follows configurational analysis with ANN-based predictive importance in a voice-shopping study. Xia et al. (2026, Section 4.3) assign theoretical relationships to PLS-SEM, prediction to ANN and configurations to fsQCA. These illustrate different combinations, not a universal order. ANN importance has a different meaning from a path coefficient, a necessity claim or a core-condition designation.

A large importance score neither supplies the direction of a relationship nor establishes that X causes Y. Name the importance method, such as sensitivity, Garson or gradient analysis, explain normalization and inspect its stability across training runs. Do not directly compare normalized ANN percentages with β or fsQCA coverage (Elafdel, 2026; Xia et al., 2026).

Separate the final test data at the outset

Specify the prediction target and splitting unit before selection. Repeated observations from people, firms or classes require a split aligned with the intended prediction task. Future information must not be used to predict the past.

Learn preprocessing within training data

Imputation, scaling, feature selection and other data-dependent choices can leak information. For out-of-sample evaluation, learned transformations, including scoring rules if re-estimated, belong within the appropriate training partition. Prespecified substantive calibration anchors remain fixed; data-estimated anchors require an explicit account.

Select the network without consulting the final test set

Report layers, nodes, activations, loss, optimizer, stopping rule, seeds and cross-validation design. Use validation for selection and the final test set for assessment after choices are frozen. Choose the split for the actual data rather than copying an application's percentage.

Compare outputs at the right level

Report errors on the same outcome scale and test observations alongside an appropriate benchmark. Interpret ANN alongside configurational findings. In-sample fsQCA consistency is not an out-of-sample prediction-accuracy measure.

This workflow is an editorial recommendation for an inspectable prediction assessment. Training-only preprocessing and separation of selection from testing are supported by the official guidance from scikit-learn developers (n.d.). Applications still require careful reading: Elafdel (2026, Section 4.4) mentions both 10-fold cross-validation and a 70/30 split without fully explaining how the two are related. Xia et al. (2026, Section 4.3) specify 80/20; a split percentage alone does not reproduce the complete evaluation. These are source descriptions, not recommended universal settings.

12. Delphi and measurement design before calibration

Ogunmola et al. (2026, Section 3) use a 24-member expert panel before analyzing student data. A useful design principle is to distinguish expert judgments about condition meaning from individual-level observations used for calibration. Consensus scores on an expert-rating scale cannot simply become anchors for a different survey scale. Express each anchor in the original units, justify it and document the membership transformation.

Manosuthi and Senachai (2026, Section 4) propose measurement before calibration: define the set, define membership meaning, design discriminating items, inspect measurement before calibration, and then transform scores. This is relevant when agreement questions produce ceiling effects. Their convenience-sample pilot involves 129 respondents, however; it does not establish that all Likert measures are inferior to trade-off items or that the proposed format outperforms alternatives across contexts.

Report expert eligibility, rounds, anonymized feedback, aggregation, consensus criteria and unresolved disagreement. Pilot the instrument with its intended respondents, checking comprehension, distributions and crossover cases. Expert consensus does not replace measurement validation or anchor-sensitivity assessment (Ogunmola et al., 2026; Manosuthi & Senachai, 2026).

Verify a calibration formula before implementation

In the supplied version of Ogunmola et al. (2026, PDF p. 12), direct substitution into Equation 6 does not reproduce the c parameters in Table 2. This guide therefore uses the Delphi design as an example of combining information sources, without adopting that formula as standard calibration code. Reproduction requires checking the function, anchors, code and actual membership at all three anchors.

13. Longitudinal data, panels and group comparisons

Ogunmola et al. (2026) observe three waves and include analyses linking earlier conditions to later outcomes. Yang et al. (2026) examine firm-year data, configurational fit over time and differences by chairman characteristics. Longitudinal data support questions about ordering and stability; they do not automatically remove confounding, reverse relationships or measurement error.

Define whether a case is a person, firm, person-wave or firm-year. Preserve unit identifiers and timing, and report unique units, observation rows, attrition and missing-data treatment. Set definitions must remain comparable over time. Recalibrating against each year's percentiles defines relative standing within each year, not automatically the same substantive level across years. A prediction split by time or unit must match the intended task and avoid leakage between learning and assessment (scikit-learn developers, n.d.).

Different recipes or coverage values across groups do not by themselves demonstrate a statistically significant difference. Define the comparison, measurement quality and calibration comparability first. Repeated observations must be respected when selecting a test; an independent-samples procedure cannot simply treat repeated firm-years as unrelated firms. This is a design consideration when reading Yang et al. (2026), not a reanalysis of their data.

The same paper describes 70 firms and 350 observations, while Table 4 lists six years, 2020–2025. This discrepancy needs clarification before reproduction. Its temporal and group questions are useful examples, but the data record should be checked rather than adopting the table as a template (Yang et al., 2026, Section 3.2 and Table 4).

14. Read applications selectively

The following source map classifies what each study actually does. Adding methods does not establish causality, and analyses of the same observations retain shared sampling and measurement limitations.

Table 6. Ten applications checked against their full texts; editorial summaries.
SourceCombinationWhat to inspect and its limits
Zu et al. (2026)AMOS/SEM + fsQCADirect and indirect associations alongside experience configurations; cross-sectional evidence does not become causal identification.
Choubey et al. (2026)CB-SEM + fsQCASeparate model tests from AI-adoption configurations. The Emerald Publishing (2026) erratum corrects affiliation only, not methods or results.
Santoso et al. (2026)PLS-SEM + fsQCAHigher-order constructs versus components; the NCA table label does not establish ceiling-based NCA.
Bai and Liu (2026)PLS-SEM + fsQCAMediation modeling versus configurations; including a mediator in a recipe does not estimate an indirect effect.
Elafdel (2026)fsQCA + ANNRecipes and predictive importance; clarify the relationship between splitting and cross-validation.
Xia et al. (2026)PLS-SEM + ANN + fsQCADistinct explanatory, predictive and configurational tasks; ANN ranking is not causal evidence.
Bai et al. (2026)NCA + fsQCASeparate ceiling outputs; absence of strong necessity evidence can coexist with sufficient combinations. Their d = 0.1 criterion is not a universal law.
Ogunmola et al. (2026)Fuzzy Delphi + longitudinal fsQCADistinguish expert and observational stages; verify the calibration formula against the parameter table.
Manosuthi and Senachai (2026)Measurement design + pilot fsQCAInspect ceilings and crossovers before analysis; the demonstration is not a comparative trial establishing superiority.
Yang et al. (2026)Text/PCA-based measures + panel fsQCA + group comparisonsCheck proxy validity, observation years and dependence among repeated firm observations.

Publisher reputation should not replace methodological assessment. An application can offer a useful design while containing reporting points that need clarification. Foundational guidance, official software documentation and checks on the actual data support implementation; applications show how a method has been used in a specific setting.

15. A minimum record for reporting the combination

  • Give every method a distinct question and contribution; do not add methods merely to produce more tables.
  • Map indicators and construct scores to sets, distinguishing higher-order constructs from components.
  • Separate SEM coefficient criteria, NCA necessity, fsQCA sufficiency and ANN prediction; do not rename one method's indices as another's.
  • For out-of-sample claims, record splitting, training-only learned transformations, seeds, versions and a benchmark.
  • For Delphi or panel designs, document expert/anchor selection, case units, timing, attrition and comparability.
  • Report complementary and divergent findings, shared limitations, sensitivity checks and anything not reproduced.
The study uses [SEM] to assess [specified relationships], [ANN if included] to compare prediction under [splitting design], and fsQCA to examine [condition combinations] for [defined outcome set]. [NCA if included] separately evaluates [necessity proposition]. Integration occurs at the interpretation stage; the indices are not treated as equivalent, and the [cross-sectional/longitudinal] design imposes [specific limits]. This is an editorial reporting template; replace the brackets with the actual analytical record.

Conclusion

Integration is useful when each analysis answers a distinct question about the research problem. Select only the necessary methods, preserve measurement quality, assess prediction appropriately and report uncertainty. A persuasive design does not require every available technique.

References

Necessity and NCA

Integrating methods

  • Greckhamer, T., Furnari, S., Fiss, P. C., & Aguilera, R. V. (2018). Studying configurations with qualitative comparative analysis: Best practices in strategy and organization research. Strategic Organization, 16(4), 482–495. https://doi.org/10.1177/1476127018786487
  • Pappas, I. O., & Woodside, A. G. (2021). Fuzzy-set qualitative comparative analysis (fsQCA): Guidelines for research practice in information systems and marketing. International Journal of Information Management, 58, 102310. https://doi.org/10.1016/j.ijinfomgt.2021.102310
  • Rasoolimanesh, S. M., Ringle, C. M., Sarstedt, M., & Olya, H. (2021). The combined use of symmetric and asymmetric approaches: Partial least squares-structural equation modeling and fuzzy-set qualitative comparative analysis. International Journal of Contemporary Hospitality Management, 33(5), 1571–1592. https://doi.org/10.1108/IJCHM-10-2020-1164
  • Richter, N. F., Schubring, S., Hauff, S., Ringle, C. M., & Sarstedt, M. (2020). When predictors of outcomes are necessary: Guidelines for the combined use of PLS-SEM and NCA. Industrial Management & Data Systems, 120(12), 2243–2267. https://doi.org/10.1108/IMDS-11-2019-0638
  • Sukhov, A., Friman, M., & Olsson, L. E. (2023). Unlocking potential: An integrated approach using PLS-SEM, NCA, and fsQCA for informed decision making. Journal of Retailing and Consumer Services, 74, 103424. https://doi.org/10.1016/j.jretconser.2023.103424

Combined-method applications and implementation guidance

  • Zu, X., He, X., Lin, M., Wang, L., & Huang, W. (2026). How do the attributes of AI-generated digital humans relate to online customer experience? Evidence from SEM and fsQCA. Asia Pacific Journal of Marketing and Logistics. Advance online publication. https://doi.org/10.1108/APJML-04-2026-0802
  • Elafdel, H. (2026). What drives Gen Z to shop by voice? A hybrid fsQCA–ANN study in an emerging market. Young Consumers, 27(8), 1091–1120. https://doi.org/10.1108/YC-07-2025-2653
  • Santoso, A. S., Desiana, P. M., Prijadi, R., Wulandari, P., & Martin-Rojas, R. (2026). Opening the black box of AI-enabled green innovation: A PLS-SEM and fsQCA study of manufacturing firms. European Journal of Management Studies. Advance online publication. https://doi.org/10.1108/EJMS-05-2026-0070
  • Choubey, S., Kumar, R., & Krishnaswamy, V. (2026). Unravelling risk-trust interplay in artificial intelligence-based systems for e-learning platforms: Evidence from CB-SEM and fsQCA. Journal of Systems and Information Technology. Advance online publication. https://doi.org/10.1108/JSIT-07-2025-0313
  • Bai, K., & Liu, Y. (2026). Bonding with AI chatbots: Anthropomorphism and changes in social support networks using PLS-SEM and fsQCA. Online Information Review. Advance online publication. https://doi.org/10.1108/OIR-06-2025-0473
  • Xia, B., Luo, Y., & Su, Y. (2026). Responsible and sustainable use of AIGC image tools in art education: An SEM–ANN–fsQCA study. Education + Training. Advance online publication. https://doi.org/10.1108/ET-05-2026-0609
  • Manosuthi, N., & Senachai, P. (2026). Designing measurement for calibration: An instrument-design framework for fsQCA applications in tourism research. ABAC Journal, 46(4), 196–221. https://doi.org/10.1108/ABAC-07-2026-0293
  • Ogunmola, G., Shavkidinova, D., Fayazuddin, M., & Imomov, I. (2026). Entrepreneurship and employability: A configurational fuzzy Delphi–fsQCA study with longitudinal evidence in emerging economies. Career Development International. Advance online publication. https://doi.org/10.1108/CDI-04-2026-0260
  • Emerald Publishing. (2026). Erratum: Unravelling risk-trust interplay in artificial intelligence-based systems for e-learning platforms: Evidence from CB-SEM and fsQCA. Journal of Systems and Information Technology. https://doi.org/10.1108/JSIT-10-2026-0953
  • Bai, Y., Liu, C., & Ma, Y. (2026). Multiple paths for green technology innovation in high-pollution firms driven by heterogeneous regulatory pressure and intrinsic traits: An integrated study of NCA and fsQCA. Chinese Management Studies. Advance online publication. https://doi.org/10.1108/CMS-10-2025-1035
  • Yang, Y., Zhou, H., & Li, Z. (2026). What facilitates the innovation efficiency of medical device firms? A configurational study on the antecedent conditions using panel fsQCA. Journal of Science and Technology Policy Management. Advance online publication. https://doi.org/10.1108/JSTPM-05-2026-0337
  • scikit-learn developers. (n.d.). Common pitfalls and recommended practices. scikit-learn documentation. Retrieved November 17, 2026, from https://scikit-learn.org/stable/common_pitfalls.html

The comparison tables and reporting language are teaching aids. Published findings are attributed to their sources. No method, effect-size threshold or agreement between methods independently establishes causality.