Running a single-factor CFA in AMOS: From model setup to reporting
If the same people answer three sets of questions, can one factor reproduce the covariance structure of all 15 indicators? This guide uses that question to show how to build the model in AMOS, check the solution and compare it with a theory-based CFA.
All selected indicators load on F. Fix one loading at 1 to set the scale and estimate the other loadings separately. The results describe how well a one-factor structure fits the data.
1. What does a single-factor CFA test?
In a single-factor confirmatory factor analysis (CFA), all selected indicators load on one latent factor, F. Suppose a theory-based CFA specifies separate factors for three sets of questions, A, B and C. The one-factor CFA asks whether one F can reproduce the covariance structure of the same indicators (Arbuckle, 2025).
Common method variance (CMV) is variation associated with the measurement method. Common method bias (CMB) concerns distortion of estimates or conclusions attributable to that method. Fit in a single-factor CFA describes how well the specified model represents the data. Attributing variance to a specific method requires a model and evidence suited to that mechanism (Podsakoff et al., 2003).
Harman’s single-factor test usually examines an exploratory factor solution. In the CFA in this guide, we specify one factor before estimation. In a simulation study, Aguirre-Urreta and Hu (2019) found limitations in the ability of Harman’s test to detect CMB. A CFA fit index, in turn, describes how well a specified model fits the data.
See the guide to distinguishing single-factor CFA and CLF for models addressing a specific source of method effects.
2. Choose the indicators and a comparison model
In this hypothetical example, the instrument has 20 indicators. A1–A5, B1–B5 and C1–C5 are rated by the same person. A different person rates D1–D5. The main example compares models using the 15 self-report indicators.
| Question | Example indicators | Comparison model |
|---|---|---|
| How well does one factor represent the self-reports? | A1–A5, B1–B5, C1–C5 (15 indicators) | Three-factor CFA on the same 15 indicators |
| How well does one factor represent the whole instrument? | Four groups from A1 through D5 (20 indicators) | Four-factor CFA on the same 20 indicators |
| How sensitive are the results to adding a method component? | Indicators exposed to the specified method | Content model and corresponding model with a CLF |
Use the same indicators, observations, estimator, missing-data treatment and mean structure in the comparison. Subtracting χ² values from models with 15 and 20 indicators compares different sets of observed variables. Using three scale means would shift the analysis from individual indicators to aggregate scores (Arbuckle, 2025).
3. Prepare the data and create a model file
Use one row per person and one column per indicator. Check variable names, valid response and missing-value codes, columns with zero variance, and planned reverse scoring. A negative loading prompts a check of item content and scoring direction. Recoding should follow the scoring rule.
In Amos Graphics, choose File → New. Choose File → Data Files, click File Name and open the checked .sav file. Save the model as, for example, CFA_one_factor_demo.amw. Keep a separate file for the three-factor CFA to avoid accidentally carrying over equality labels, residual covariances or CLF paths (Arbuckle, 2025).
The example uses maximum likelihood (ML) and treats indicators as continuous. Consider the distribution and independence of observations when using conventional ML fit tests and standard errors. Items with few ordered categories, extreme skew or clustered observations may call for a different method. The Measure property in SPSS records the variable’s declared level of measurement (Arbuckle, 2025). For selecting a CFA estimator for ordered categorical items, see Flora and Curran (2004).
4. Draw one factor and set its scale
The schematic shows the input model for 15 indicators. The value of 1 on F → A1 sets the scale of F. Fixing each residual-to-indicator path at 1 places residual variance on the same scale as the indicator variance.

- Define the 15 observed variables. Draw rectangles and use Object Properties to name them A1–A5, B1–B5 and C1–C5. Match the data column names.
- Draw one oval for F. Draw a one-headed arrow from F to each of the 15 indicators.
- Give each indicator a separate residual. Add e1–e15. Fix each path from residual to indicator at 1 and estimate the associated residual variance. In this example, residual covariances are zero.
- Use a marker loading to scale F. Double-click F → A1. Enter 1 under Object Properties → Parameters → Regression weight. Estimate the variance of F freely (Amos Development Corporation, n.d.-b).
- Estimate the remaining loadings separately. Leave labels blank or give each path its own label. A shared label imposes an equality constraint (Arbuckle, 2025).
- Check the input diagram. Count one factor, 15 indicators and 15 residuals. Verify the marker loading and variable names, then save.
The marker loading sets the unit of F
Fixing the unstandardized loading of A1 at 1 sets the scale of F. The standardized A1 loading still depends on the variances of F and A1. The residual variance of A1 is still estimated (Arbuckle, 2025).
5. Specify estimation and request output
Open View → Analysis Properties → Estimation to confirm the estimator. Keep missing-data treatment and the mean structure the same in the comparison model and report both settings (Arbuckle, 2025).
In Output, select Standardized estimates to obtain standardized loadings (Amos Development Corporation, n.d.-a). Select Squared multiple correlations if you also want the proportion of each indicator’s variance accounted for by F within the model (Arbuckle, 2025). AMOS reports conventional fit indices after estimation. Use bootstrapping or user-defined estimands when an additional uncertainty estimate or model quantity calls for them.
When Estimate means and intercepts is enabled, AMOS leaves GFI, PGFI, AGFI and RMR unreported. Choose the mean structure to suit the data, missing-data treatment and research question. Report available fit indices for the model you estimated (Amos Development Corporation, n.d.-c).
6. Estimate the model and check the solution
Choose Analyze → Calculate Estimates, then View → Text Output. Start with Notes for Model and accompanying warnings. Check convergence, identification and admissibility before reporting fit. Negative factor or residual variances and other out-of-range estimates warrant investigation (Arbuckle, 2025).
Counting degrees of freedom for 15 indicators
The covariance matrix contains 15 × 16/2 = 120 distinct entries. There are 14 free loadings, 15 residual variances and one variance for F. With 30 parameters, the expected degrees of freedom equal 120 − 30 = 90.
If AMOS reports a different value, check the number of indicators, duplicated path labels, residual covariances and other constraints. With a mean structure that estimates one intercept per indicator and fixes the mean of F at zero, each count rises by 15, so the degrees of freedom can stay the same (Arbuckle, 2025).
For negative variances or serious warnings, see the guide to diagnosing CLF errors. The data, scaling and warning checks also apply to a single-factor CFA.
7. Find the fit indices and record the comparison
| Output | Typical location | Use |
|---|---|---|
| Warnings, moments, parameters and df | Notes for Model | Check specification and admissibility |
| χ², df, p, CMIN/DF | Model Fit → CMIN | Use the Default model row |
| CFI, TLI | Model Fit → Baseline Comparisons | Read the estimated model’s values |
| RMSEA, LO 90, HI 90 | Model Fit → RMSEA | Report the corresponding confidence level |
| Standardized loadings | Estimates → Scalars → Standardized Regression Weights | Inspect each indicator’s loading on F |
| Factor and residual variances | Estimates → Scalars → Variances | Check for inadmissible estimates |
CMIN/DF equals χ²/df. CFI and TLI evaluate fit relative to a baseline model. Read RMSEA as a measure of approximate fit and report its confidence interval. Use the Default model row and the confidence level AMOS reports (Arbuckle, 2025).
| Model | χ² | df | CFI | TLI | RMSEA [confidence interval] |
|---|---|---|---|---|---|
| Theory-based three-factor CFA | [enter] | [enter] | [enter] | [enter] | [enter] |
| Single-factor CFA | [enter] | [enter] | [enter] | [enter] | [enter] |
Enter the results from your own models. For an item-by-item comparison, save the standardized loadings from both models along with warnings and analysis settings.
8. Interpret fit in a CMB assessment
Poor single-factor fit means that the one-factor structure struggles to reproduce the data under the tested specification. A better-fitting, admissible multifactor model supports the distinction between constructs in this comparison. Smaller or differently structured method effects can still occur (Podsakoff et al., 2003).
If the single-factor model fits, examine whether the constructs overlap or share a broader substantive factor. The name F is a model label. Its interpretation as a method factor needs support from the design or other relevant evidence. CFI, χ² and the loadings on F describe the fitted model as specified.
In a multifactor CFA, a one-factor representation can correspond to setting factor correlations to 1. The factor covariance matrix can be singular at this boundary, where the conventional χ² difference reference distribution may fail. Verify the assumptions before calculating a p-value. Describe the fit comparison when the usual test conditions have not been established (Stoel et al., 2006).
Save the original model before making changes. Any modification guided by an index, such as dropping an item or correlating residuals, needs a substantive or design-based reason. Explain which question the revised model addresses.
9. Check common specification and reporting errors
| Error | Consequence | Check |
|---|---|---|
| Keep A, B and C and add F | The diagram contains multiple factors | Count the ovals and trace the measurement paths |
| Give all loadings one label | Adds equal-loading constraints | Check F → A1 is fixed at 1 and free loadings have distinct labels |
| Use scale means in place of items | Changes the level of measurement | Compare data column names with the indicator list |
| Compare 15- and 20-indicator models with Δχ² | Uses different observed variables | Match indicators and estimation settings |
| Copy fit from the Saturated model | Reports a different model | Use the Default model row |
| Add MI-suggested paths simply to improve fit | Changes the comparison question | Save the original and record the reason for each modification |
| Use poor fit to claim “no CMB” | Goes beyond the CFA result | Limit the conclusion to the tested one-factor representation |
10. Reporting example and practice worksheet
Fill in the reporting example with your results
We estimated a single-factor CFA on [number] indicators [indicator set and rater source]. All indicators loaded on F. We fixed one loading at 1 to scale the factor and estimated the other loadings separately. Both models shared the same [estimator], [missing-data treatment] and [mean structure].
The single-factor CFA gave χ²([df]) = [value], CFI = [value], TLI = [value], and RMSEA = [value] with a [level]% confidence interval of [lower, upper]. Compared with the [number]-factor model on the same indicators, the results showed [describe observed fit]. The comparison concerns the one-factor structure as specified.
- Each selected indicator loads on F and has a separate residual.
- One marker loading is fixed at 1, and the other loadings and variance of F are estimated as planned.
- The models share variables, observations, missing-data treatment and estimator.
- Warnings and variances were checked, and the Default model results and RMSEA interval were saved.
Conclusion
The example specifies one F, a marker loading and 15 separate residuals. Comparing it with the content CFA helps assess whether the data call for a more differentiated structure. Interpret that comparison alongside the rater sources and data collection design when discussing method bias.
How to cite this guide
In the text, use (Le Minh, 2026) or Le Minh (2026).
Reference list entry
Le Minh. (2026, November 19). Running a single-factor CFA in AMOS: From model setup to reporting. SmartPLS Lê Minh. https://smartplsleminh.com/en/bai-viet/huong-dan-chay-single-factor-cfa-amos
References
- Aguirre-Urreta, M. I., & Hu, J. (2019). Detecting common method bias: Performance of the Harman’s single-factor test. ACM SIGMIS Database: The DATABASE for Advances in Information Systems, 50(2), 45–70. 10.1145/3330472.3330477
- Amos Development Corporation. (n.d.-a). Standardized estimates. Amos Development Corporation
- Amos Development Corporation. (n.d.-b). To set a parameter equal to a constant. Amos Development Corporation
- Amos Development Corporation. (n.d.-c). Why didn’t Amos report GFI, PGFI, AGFI and RMR? Amos Development Corporation
- Arbuckle, J. L. (2025). IBM SPSS Amos 31 user’s guide. IBM. IBM
- Flora, D. B., & Curran, P. J. (2004). An empirical evaluation of alternative methods of estimation for confirmatory factor analysis with ordinal data. Psychological Methods, 9(4), 466–491. 10.1037/1082-989X.9.4.466
- Podsakoff, P. M., MacKenzie, S. B., Lee, J.-Y., & Podsakoff, N. P. (2003). Common method biases in behavioral research: A critical review of the literature and recommended remedies. Journal of Applied Psychology, 88(5), 879–903. 10.1037/0021-9010.88.5.879
- Stoel, R. D., Galindo Garre, F., Dolan, C., & van den Wittenboer, G. (2006). On the likelihood ratio test in structural equation modeling when parameters are subject to boundary constraints. Psychological Methods, 11(4), 439–455. 10.1037/1082-989X.11.4.439