Top of page
Skip to main content

Reading CLF evidence alongside Harman, PCA and nonresponse checks

A CLF diagram describes a model specification. Paired outputs are needed to assess changes. Harman, PCA and early–late response comparisons also answer different questions and should retain their original labels.

Reading principle. Separate what is visible in the published diagram, what the authors report in the narrative and what can be recalculated from available numbers.
Start reading

1. Put the diagram in its measurement context

Deep et al. (2026) study construction workers’ climate-resilient productivity from a job demands–resources perspective. The main sample has 420 complete responses; the pilot has 34 valid responses. The CB-SEM/AMOS model covers work environment, employee well-being, strategic planning and climate-resilient productivity.

Section 4.2 describes five response levels from “not important” to “extremely important.” Preserve those importance anchors rather than changing them to disagreement/agreement. Identical numeric codes 1–5 do not imply identical measurement meanings.

The source reports 34.250% in the Harman account, 21.569% in the PCA/varimax account and early/late groups of 210 each. These are different analyses, not interchangeable estimates of bias.

2. Read the original CLF figure without inventing constraints

Original Figure 3 from Deep et al. (2026): published marker or CLF model, with original labels and estimates.
Original Figure 3. Deep et al. (2026), PDF page 15. Source article. Select the figure to open it at full size. This is the authors’ published figure, not a re-estimation for this guide.

Figure 3, PDF page 15, retains four substantive factors and adds CLF paths to 22 observed indicators: six CRP, five WE, five EW and six SP indicators. The trait factors covary and the indicators have individual errors. The original figure is reproduced here for examination (Deep et al., 2026).

Table 1. What a diagram can and cannot establish
Visible elementWhat it showsAdditional output required
CLF paths to indicators.An added common component.Scaling, free/fixed paths and equality constraints.
Four trait factors.Retained substantive constructs.Match to the original CFA’s items and orientation.
Displayed coefficients.One depicted solution.Standardisation, precision, SEs and warnings.
Individual errors.Residual components.Residual variances and any inadmissible estimates.

One diagram does not provide every before/after loading difference. Structural-path sensitivity requires a pair of structural models as well. Curved factor-covariance arrows in a CFA are not directional hypothesis paths.

The narrative reports no significant loading or path changes. Keep this attributed to the authors rather than presenting an independent recalculation. Equal-looking rounded coefficients do not reveal whether parameters were constrained equal; near-zero labels do not recover Var(M) or a method-variance proportion.

3. Reconcile extraction, rotation and variance percentages

The CMB passage compares 34.250% with 50%. The exploratory section describes PCA with varimax and a first-component eigenvalue of 6.168 alongside 21.569%. Before treating the percentages as contradictory, check extraction, rotation, items, sample and the output column being cited (Deep et al., 2026).

Rotation redistributes variance among retained components, so pre- and post-rotation percentages can differ. The published narrative alone does not identify all relevant columns. There is also a conditional arithmetic check: if the PCA used the same 22 standardised variables visible in Figure 3, then 6.168/22 × 100 ≈ 28.036%, not 21.569%. This does not establish the cause. The eigenvalue and percentage could refer to different columns or variable sets; obtain the original output.

Table 2. Reconciliation record for the two variance accounts
FieldHarman accountPCA/varimax account
Reported percentage.34.250%.21.569%.
Items and N.Retrieve the original command/output.Retrieve the original command/output.
Extraction and rotation.Verify actual settings.PCA and varimax are described.
Variance column.Initial, extraction or rotation?Initial, extraction or rotation?

In SPSS, use Analyze → Dimension Reduction → Factor, record the selected variables, extraction and rotation, then save the complete Total Variance Explained table. Do not copy a percentage without its column. Harman’s detection limitations remain even if its reported result is below a chosen threshold (Aguirre-Urreta & Hu, 2019).

4. Keep nonresponse assessment separate

Table 4 compares 210 early and 210 late respondents. Reported chi-square p-values are .313 for project type, .450 for job role and .046 for UAE work experience, with Cramér’s V of .092, .117 and .138 respectively. Other t-tests and Mann–Whitney results are reported in the table. “Every test was nonsignificant” would omit the .046 result; the authors acknowledge that exception and describe its effect as small.

Early–late comparisons use later respondents as an indirect indication of potential participation differences, under an extrapolation argument discussed by Armstrong and Overton (1977). They do not directly observe complete nonrespondents and do not isolate method variance shared by self-reported constructs.

A favourable nonresponse check therefore does not establish no CMB. A small distribution difference also does not establish bias in the SEM paths. For categorical codes such as project type or job role, means depend on arbitrary numbering; inspect distributions, cell counts and suitable tests rather than treating the codes as natural quantities.

5. From a diagram to a reproducible CLF record

  1. Freeze the codebook

    Retain anchors, direction, missing values and pilot/main-study distinctions. Reconcile the 22 indicators with the actual analysis file.

  2. Save the original CFA

    Export the item-matched standardised and unstandardised loadings, factor covariance record, χ², df and fit indices.

  3. Document the CLF specification

    Record scaling, method–trait relations and constraints. Check identification and the admissibility of the solution before interpretation (IBM, 2017).

  4. Construct paired tables

    Match each item’s loading before/after and calculate signed and absolute changes. If paths are discussed, provide their separate structural comparison and uncertainty.

  5. Reconcile exploratory outputs

    Save the full variance table, variable list, sample, extraction and rotation settings. Do not infer missing column labels.

  6. Report response checks separately

    Preserve the early–late group definition, contingency counts, tests, effects and exceptions. Explain the indirect nature of the nonresponse argument.

6. Reporting template

On [N], the [specified extraction, item set and rotation] yielded [percentage in the named column]. The CLF model used [scaling and constraints]; paired loadings changed [range and maximum]. Structural sensitivity was [examined with outputs / not independently available]. Early–late response comparisons used [groups and tests], with [effects and exceptions]. These provide evidence about distinct issues under their stated assumptions.
Table 3. Evidence to retain for each claim
ClaimNecessary record
Loadings changed little.Original and CLF loadings matched by item.
Paths changed little.Comparable structural coefficients and uncertainty.
The variance percentages are reconciled.Full extraction/rotation output and item set.
No substantial early–late difference was observed.Tests, effects and exceptions, including work experience.

Conclusion

A complete CLF record includes the diagram, specification, admissible solution and paired outputs. Keep Harman, PCA and nonresponse evidence attached to their own questions. That makes the limits of each conclusion visible.

References

Study examined

  • Deep, S., Kumar, A., Kumari, P., Jha, K. N., Tripathi, P. M., & Raszkowski, A. (2026). Understanding the climate-resilient productivity of construction workers: A job demands–resources perspective. Engineering, Construction and Architectural Management. Advance online publication. DOI.

Methodological sources

  • Aguirre-Urreta, M. I., & Hu, J. (2019). Detecting common method bias: Performance of the Harman’s single-factor test. ACM SIGMIS Database: The DATABASE for Advances in Information Systems, 50(2), 45–70. DOI.
  • Armstrong, J. S., & Overton, T. S. (1977). Estimating nonresponse bias in mail surveys. Journal of Marketing Research, 14(3), 396–402. DOI.

Official software documentation