Assessing CMB and CMV in CB-SEM and PLS-SEM
Start with the possible sources of bias in the survey design. Select an assessment that addresses those sources, then examine the sensitivity of the substantive relationships. CB-SEM and PLS-SEM require distinct workflows.
Three tasks in CMB assessment
- Prevention
Match design precautions to a plausible mechanism
- Assessment
Specify the procedure and check its assumptions
- Sensitivity
Compare focal relationships and their uncertainty
Conceptual diagram. Conceptual framework prepared by Lê Minh, not software output.
Source: Lê Minh · Conceptual illustration, not software output.1. Define the question before selecting a diagnostic
Common method variance (CMV) refers to variance associated with the measurement method. Common method bias (CMB) concerns distortion of the estimates used to answer the research question. A method component need not distort every relationship equally. Conversely, a diagnostic that fails to detect a problem cannot cover every potential source of method effects (Podsakoff et al., 2012, 2024).
Before opening the software, identify the suspected mechanism, the information that can reveal it, and the relationship whose interpretation matters. Asking how the X–Y relationship changes under a stated method specification is more useful than searching for a single number that permits a declaration of “no CMB.”
| Task | Appropriate evidence | Limit |
|---|---|---|
| Prevention | Actual question design, respondents, timing and collection conditions. | A precaution does not demonstrate the absence of subsequent bias. |
| Diagnosis | Results from an assessment with stated assumptions. | Detection is not automatic correction. |
| Adjustment or sensitivity analysis | Comparable coefficients, confidence intervals and conclusions under defensible models. | The adjusted model still depends on its specification and measurements. |
2. Plan prevention while designing the survey
Evaluation apprehension, ambiguous wording, shared context and response tendencies are design concerns. Separating sources or occasions is useful when it addresses a plausible mechanism while preserving the construct being measured. Neither separation nor randomisation is a universal remedy (Podsakoff et al., 2003).
Map the sources
Record who reports each construct, when they report it and what information they provide. Distinguish subjective evaluations from factual information such as age, years of experience or revenue.
Review the instrument
Pilot comprehension, avoid leading and double-barrelled questions, and consider separation of questionnaire sections without removing context respondents need.
Collect the supplementary information you will need
If a measured marker is planned, choose its items and document substantive independence before fieldwork. Generated values after collection cannot replace respondents’ actual marker answers.
Specify the comparisons
Record the baseline and supplementary models, focal relationships, missing-data rules, software and version. Keep a log of later departures.
3. Choose a route consistent with the estimator
For CB-SEM, establish the baseline measurement model, determine whether a marker was actually measured, select a justified CFA-marker or method-factor specification, check identification and the solution, and compare the substantive relationships. For PLS-SEM, establish measurement quality, distinguish the relevant VIFs, assess the marker if one was collected, and use an explicitly defined PLS procedure before comparing estimates.
A CLF fitted separately in AMOS does not automatically adjust PLS estimates. Adding a variable in SmartPLS does not, by itself, reproduce the measured latent marker variable procedure. Chin et al. (2012) demonstrate problems with the particular unmeasured latent method construct implementation they examine in PLS; Chin et al. (2013) develop a measured-marker approach. These are different procedures.
4. A practical CB-SEM workflow
Keep a defensible baseline
Check coding, response categories, the estimator, model identification and inadmissible results such as negative residual variances. Choose estimation for the measurement level and distribution rather than treating a default option as appropriate for every questionnaire.
Save factor loadings, factor correlations or covariances, fit statistics, structural coefficients and their standard errors or confidence intervals. Keep the indicators, effective sample and estimation conditions comparable in the supplementary model. Changing items or cases at the same time prevents a clean attribution of differences to the method specification.
When a marker was measured
Williams et al. (2010) set out the comprehensive CFA marker technique. Its models serve different purposes; their names should accompany the actual scaling, constraints and comparison sequence.
| Models | Purpose | Information to retain |
|---|---|---|
| CFA and Baseline | Establish measurement and the reference without method loadings on substantive indicators. | Marker parameters and its relations with substantive factors. |
| Method-C | Introduce constrained method effects according to the source procedure. | Which loadings are constrained and which are estimated. |
| Method-U | Allow method effects to vary according to that procedure. | Identification and an admissible solution. |
| Method-R | Fix substantive factor correlations to their Baseline values; compare with the retained Method-C or Method-U model to assess sensitivity. | The parameters fixed and the appropriate comparison model. |
This table is a reading guide, not a substitute for the original model specifications. Convergence alone does not establish that the model is identified or its solution interpretable.
When using an unmeasured common latent factor
State the measurement equation, method loadings, factor scaling and assumed relations between the method and substantive factors. Fixing a variance or loading addresses scaling, but does not settle identification of the complete model. An unmeasured factor can capture shared variance beyond the particular bias mechanism of interest (Podsakoff et al., 2003, 2012).
In AMOS, keep separate baseline and method-model files, request standardised and unstandardised estimates, and inspect warnings, residual variances and parameter stability. A chi-square difference comparison requires appropriate nesting, the same data and a suitable estimation-specific test. Do not subtract arbitrary chi-square statistics.
Return to the substantive question
Compare direction, magnitude and uncertainty in the focal coefficients. Report improvement in fit separately from sensitivity of the relationships. A loading difference below .20, or a CLF percentage below a chosen value, is not a general certificate that CMB is absent (Podsakoff et al., 2024).
5. A practical PLS-SEM workflow
Save the original measurement results, construct scores when required, paths, indirect effects, R² and confidence intervals. Identify the estimator and any variant. Bootstrapping estimates uncertainty under the specified data and procedure; it does not remove systematic method bias.
| VIF | Variable set | Interpretation |
|---|---|---|
| Indicator | Indicators within the relevant measurement block. | Collinearity among those indicators. |
| Structural | Predictors of a particular endogenous construct. | Collinearity in that structural equation. |
| Full collinearity | Each construct score regressed on all other scores in the defined set. | A full-collinearity diagnostic under that approach. |
SmartPLS (n.d.) distinguishes VIFs by the variable set involved. Kock’s (2015) proposed 3.3 criterion concerns his full-collinearity assessment. Name the VIF before invoking that proposal. High collinearity does not uniquely identify a method-bias cause.
If a marker was collected, justify both substantive independence and its ability to reflect the relevant measurement process. Years of experience can be a useful control, but its different name does not establish that it captures the response tendencies of perception items. Marker selection needs contextual reasoning, even when a previously developed scale is available (Miller & Simmering, 2023).
Apply the measured-marker procedure being cited, including the actual item set and adjustment steps (Chin et al., 2013). Compare focal paths, indirect effects and confidence intervals before adding R² to the report. Small ΔR² or nonsignificant marker paths cannot alone establish the absence of CMB.
The critique of a particular PLS implementation in Chin et al. (2012) should not be generalised to every method-factor model. Ding et al. (2023) investigate an improved CFA-based ULMC specification using identifying indicators and reparameterisation, with simulation performance conditional on specification and sample size. This is advanced further reading, not a default SmartPLS operation. Its equations, constraints and simulation conditions need to be read before implementation. Ding et al. (2023)
6. Avoid conclusions beyond the evidence
| Result | Unsupported inference | Next step |
|---|---|---|
| First Harman factor below 40% or 50%. | The data are free of CMB. | Recognise the limited detection performance documented by Aguirre-Urreta and Hu (2019). |
| Good CFA fit or satisfactory HTMT. | No method variance remains. | Assess the method hypothesis explicitly. |
| Low indicator VIFs. | A full-collinearity test has been completed. | Identify the regressions and variable set. |
| Small R² changes after adding a variable. | The variable removed CMB. | Assess its validity and sensitivity of substantive estimates. |
| A method model fails to converge. | CMB must be present, or must be absent. | Investigate identification, specification, data and estimation. |
7. Make the assessment reproducible
We identified [plausible method mechanisms] and implemented [actual design precautions]. The supplementary assessment used [technique and source] with [measured variables, specification and assumptions]. Models were estimated using [software, version and estimator]. For [focal relationship], the estimate changed from [estimate and CI] to [estimate and CI]. This provides evidence about [scope] under [conditions and limitations].
Retain item sources, response anchors, coding, effective samples, model files, parameter constraints and the complete comparison outputs. Label published results, arithmetic recalculations and hypothetical examples separately. The linked practice series applies this record to ten published studies.
Conclusion
CMB assessment begins with measurement design and ends with the interpretation of substantive relationships under explicit assumptions. Use the correct procedure name, preserve comparable conditions and report what changed, including the uncertainty. That record is more informative than a universal pass/fail declaration.
References
Methodological sources
- Aguirre-Urreta, M. I., & Hu, J. (2019). Detecting common method bias: Performance of the Harman’s single-factor test. ACM SIGMIS Database: The DATABASE for Advances in Information Systems, 50(2), 45–70. DOI.
- Chin, W. W., Thatcher, J. B., & Wright, R. T. (2012). Assessing common method bias: Problems with the ULMC technique. MIS Quarterly, 36(3), 1003–1019. DOI.
- Chin, W. W., Thatcher, J. B., Wright, R. T., & Steel, D. (2013). Controlling for common method variance in PLS analysis: The measured latent marker variable approach. In H. Abdi, W. W. Chin, V. Esposito Vinzi, G. Russolillo, & L. Trinchera (Eds.), New perspectives in partial least squares and related methods (pp. 231–239). Springer. DOI.
- Kock, N. (2015). Common method bias in PLS-SEM: A full collinearity assessment approach. International Journal of e-Collaboration, 11(4), 1–10. DOI.
- Miller, B. K., & Simmering, M. J. (2023). Attitude toward the color blue: An ideal marker variable. Organizational Research Methods, 26(3), 409–440. DOI.
- Podsakoff, P. M., MacKenzie, S. B., & Podsakoff, N. P. (2012). Sources of method bias in social science research and recommendations on how to control it. Annual Review of Psychology, 63, 539–569. DOI.
- Podsakoff, P. M., MacKenzie, S. B., Lee, J.-Y., & Podsakoff, N. P. (2003). Common method biases in behavioral research: A critical review of the literature and recommended remedies. Journal of Applied Psychology, 88(5), 879–903. DOI.
- Podsakoff, P. M., Podsakoff, N. P., Williams, L. J., Huang, C., & Yang, J. (2024). Common method bias: It’s bad, it’s complex, it’s widespread, and it’s not easy to fix. Annual Review of Organizational Psychology and Organizational Behavior, 11, 17–61. DOI.
- Simmering, M. J., Fuller, C. M., Richardson, H. A., Ocal, Y., & Atinc, G. M. (2015). Marker variable choice, reporting, and interpretation in the detection of common method variance: A review and demonstration. Organizational Research Methods, 18(3), 473–511. DOI.
- Williams, L. J., Hartman, N., & Cavazotte, F. (2010). Method variance and marker variables: A review and comprehensive CFA marker technique. Organizational Research Methods, 13(3), 477–514. DOI.
Official software documentation
- SmartPLS. (n.d.). PLS-SEM glossary. Retrieved November 18, 2026, from Official documentation.
Ding, C. G., Chen, C.-F., & Jane, T.-D. (2023). Improving the performance of the unmeasured latent method construct technique in common method variance detection and correction. Journal of Organizational Behavior, 44(3), 519–542. https://doi.org/10.1002/job.2673
